  film capacitors ? power factor correction thyristor module tsm-lc100 series/type: tsm-lc100 ordering code: B44066T0100E402 date: august 2010 version: 2 ? epcos ag 2010. reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without epcos' prio r express consent is prohibited. entered in headers and footers! please fill in the film capacitors ? power factor correction thyristor module tsm-lc100 ordering code: (top right header bar) B44066T0100E402 series/type: (top right header bar) tsm-lc100 preliminary data (optional): (if necessary) department: film pfc pm date: august 2010 version: 2
film capacitors ? power f actor correction B44066T0100E402 thyristor module tsm-lc100 tsm-lc100 film pfc pm august 2010 please read cautions and warnings and page 2 of 6 important notes at the end of this document . characteristics ? fast electro nically controlled self observing thyristor switch ? usage in dynamic (fast) power factor correction systems ? for capacitive loads up to 100 kvar features ? easy installation: self-check after turn-on of main voltage ? display and control via led-display ? permanent self-controlling: voltage parameters, phase sequence, capacitor output, temperature ? forced cooling by fan, temperature controlled technical data and specifications dimensions 157 240 195 mm (w h d) weight 5.5 kg voltage 3 400 v maximum voltage - in conventional pfc systems (without reactors) - in detuned pfc systems (7% detuning) - in detuned pfc systems (14% detuning) 440 v 440 v (no upward tolerance permitted) 400 v frequency 50 hz/60 hz max. power 75 ... 100 kvar max. rms current* (*no continuous current ? thermal load has to be considered) 200 a auxiliary supply 230 v ac (needed for fan) via terminal clamp; automatically controlled cooling, over temperature switch off activation 10 ? 24 v dc (20 ma), via terminal clamp; internally insulated
film capacitors ? power f actor correction B44066T0100E402 thyristor module tsm-lc100 tsm-lc100 film pfc pm august 2010 please read cautions and warnings and page 3 of 6 important notes at the end of this document . monitoring net voltage, temperature and operation status note: before re-switching after temperature fault, heat sink temperature must be below 50 c (hysteresis)! display 2 leds/phase: operation/error, triggering signal power circuit direct connection 4-pole via bus bar cable lug 70 mm 2 , d = 10 mm), connection from bottom power dissipation p v (w) = 2.0 i (in a); at 400 v/100 kvar typical 300 w thermal warming 20 k above ambient temperature at nominal load fuse superfast 250 a at 100 kvar
film capacitors ? power f actor correction B44066T0100E402 thyristor module tsm-lc100 tsm-lc100 film pfc pm august 2010 please read cautions and warnings and page 4 of 6 important notes at the end of this document . dimensional drawing
film capacitors ? power f actor correction B44066T0100E402 thyristor module tsm-lc100 tsm-lc100 film pfc pm august 2010 please read cautions and warnings and page 5 of 6 important notes at the end of this document . cautions and warnings general x thyristor modules tsm series may only be used for the purpose they have been designed for. x thyristor modules tsm series may only be used in combination with appropriate pre-switched grid separator device. x thyristor modules have to be projected in such a way that in case of any failure no uncontrolled high current and voltages may occur. x the devices in operation have to be protected against moisture and dust, sufficient cooling has to be assured. attention due to the switching principle of the thyristor module the power capacitors are permanently loaded to the peak value of the grid voltage (dc voltage) even when switched off. therefore following rules have to be obeyed in any case: x for standard pfc-systems (without reactors) power capacitors of 440 v nominal voltage have to be used; for detuned systems pfc capacitors of 525 v nominal voltage have to be used. x due to the high voltage (2 x peak value of nominal voltage) that occurs, the discharge resistors of the power capacitors have to be replaced by special types (accessory ew22). x in dynamic systems with tsm modules no fast discharge reactors may be used (reactor = dc- wise short circuit). x for standard pfc-systems 2 current limiting reactors are mandatory per thyristor module (accessory bd100). x thyristor modules in general have to be protecte d by superfast electronic fuses. principles for dimensioning have to be considered. fuses in the system have to be marked. x due to the special switching, the pfc capacit ors are fully loaded even when the particular step has been switched off. protection against contact has to be guaranteed. warning signals in the systems are required. x even in switched off state no electrical isolati on is achieved for electronic switches. therefore parts of the systems may not be touched after switching off the complete system before the capacitors have been completely discharged. failure to follow cautions may result, worst case, in premature failures or physical injury. note for detailed information about pfc capacitors and cautions, refer to the latest version of epcos pfc product profile.
important notes page 6 of 6 the following applies to all products named in this publication: 1. some parts of this publication contain statements about the suitability of our products for certain areas of application . these statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. we nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. as a rule, epcos is either unfamiliar with individual cu stomer applications or less familiar with them than the customers themselves. for these reasons , it is always ultimately incumbent on the customer to check and decide whether an epcos product with the properties described in the product specification is suitable for use in a particular customer application. 2. we also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. in customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must theref ore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component. 3. the warnings, cautions and product-specific notes must be observed. 4. in order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous) . useful information on this will be found in our material data sheets on the internet (www.epcos.com/material). should you have any more detailed questions, please contact our sales offices. 5. we constantly strive to improve our products. consequently, the products described in this publication may change from time to time . the same is true of the corresponding product specifications. please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. we also reserve the right to discontinue production and delivery of products . consequently, we cannot guarantee that all products named in this publication will always be available. the aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. 6. unless otherwise agreed in individual contracts, all orders are subject to the current version of the ?general terms of delivery for products and services in the electrical industry? published by the german electrical and electronics industry association (zvei) . 7. the trade names epcos, baoke, alu-x, ceradiode, csmp, cssp, ctvs, deltacap, digisimic, dssp, miniblue, minicell, mkd, mkk, mlsc, motorcap, pcc, phasecap, phasecube, phasemod, phicap, siferrit, sifi, sikorel, silvercap, simdad, simic, simid, sineformer, siov, sip5d, sip5k, thermofuse, windcap are trademarks registered or pending in europe and in other countries. further information will be found on the internet at www.epcos.com/trademarks.


▲Up To Search▲   

 
Price & Availability of B44066T0100E402

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X